EZ-Series Battery Chargers

[cs_content][cs_element_section _id=”1″ ][cs_element_row _id=”2″ ][cs_element_column _id=”3″ ][cs_element_image _id=”4″ ][/cs_element_column][cs_element_column _id=”5″ ][cs_element_text _id=”6″ ][cs_content_seo]For charging and maintaining batteries used for engine starting and control.Which is the easiest charger to procure, install and use? The EZ Automatic Battery Charger! Read the following to see why it’s so – o – o – o – o – o EASY!FeaturesAC line compensationPrecision voltage regulationCompletely solid stateConvection cooled – no fanFloat, high-rate and AC-ON LEDsAutomatic timed high-rate chargingCompletely self protectedFully isolated – no direct AC to DC connectionAlarm package including high & low volts, rectifier fail and AC fail LEDs with a common relayDC voltmeter and ammeterCurrent limited – no cranking disconnect requiredCurrent limit factory sealedCannot discharge battery during AC failureEasily field adjustable without battery connectionControl switch for manual float, timed high rate or automatic\n\n[/cs_content_seo][cs_element_accordion _id=”7″ ][cs_element_accordion_item _id=”8″ ][cs_content_seo]Data Sheet\n\nEZ-Series Battery Charger Data Sheet (PDF)\n\n[/cs_content_seo][/cs_element_accordion][/cs_element_column][/cs_element_row][/cs_element_section][cs_element_section _id=”9″ ][cs_element_row _id=”10″ ][cs_element_column _id=”11″ ][cs_element_text _id=”12″ ][cs_content_seo]Simply Easy!To InstallEasily accessed connections and external mounting holes makethe job simple.To AdjustAll adjustments are factory set but if changes are needed, they are easily made before the battery is connected! Adjust the float and high-rate levels and set the high and low alarm points using only a precision voltmeter. There is no need to bring the battery voltage up and down to set these voltage levels. The autocharge, rectifier fail and AC fail alarms require no adjustments. Current limit is factory set and sealed. No need to adjust even if changing the control board.To MaintainShould something go awry, all major components are easily exchanged. A single PC-board is plugged in and switched in minutes. No quess work in setting alarm levels. Just adjust before the battery is reconnected.To SpecifyYour requirements are met by standard features (See features list). Specify only the DC volts and amps needed.To OrderUnits shipped from stock. If desired, specify quantity and type of cells or float and high-rate charge voltages for exact factory setting.OptionsAC line cordTemperature compensationDripshieldAC on-off switchSpecificationsAC Input: 117V AC +/-10%, 60 Hz +/-5%DC Voltage Regulation: +/-1/2%Protection: AC & DC fusesHousing: stainless steelMounting: Simple wall mtg.Meters: DC volts & amps 5% accuracyTemperature range: -20 to 50╦ÜCModelVolts Amps Dimensions (H” x W” X D”) Weight (Lbs.) EZ-12-1012.75 x 9.5 x 7.515EZ-24-612.75 x 9.5 x 7.515EZ-24-1012.75 x 9.5 x 7.520\n\n[/cs_content_seo][/cs_element_column][/cs_element_row][/cs_element_section][/cs_content]